[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [cobalt-security] HDD problems



paul jacobs schrieb:

> Crap!, I got this message this morning and now I will have to take the
> box down and look at it.
>
> Warning: RAID device <md3> has a dead partition!
>
> [/proc/mdstat]
>   Personalities : [linear] [raid0] [raid1] [raid5] [translucent]
>   read_ahead 1024 sectors
>   md1 : active raid1 hdc1[1] hda1[0] 768000 blocks [2/2] [UU]
> resync=2% finish=62.0min
>   md3 : active raid1 hdc3[1] hda3[0](F) 205056 blocks [2/1] [_U]
>   md4 : active raid1 hdc4[1] hda4[0] 37947072 blocks [2/2] [UU]
>   md6 : active raid1 hdc6[1] hda6[0] 131456 blocks [2/2] [UU]
>   unused devices: <none>

maybe craped ... some has mentioned that the RaQ4 is running good as
long as he stays up,
and fail if it goes down in fact that it cools down and that might
dislike the hardware ... maybe
... but I guess ... crap ... the 90 $ for a new harddisk isn't worth to
play games like "maybe not dead"

>
> Has anyone seen this problem before?, if so what is it?, is the drive
> dead or do I just need to repair the dead partition?
> What drives are in the older RAQ4R models so I can order a few... this
> is the first time the drive has died on us but, the box is almost 2
> years old so we expected them to go out soon. 

do a

#> cat /var/log/kernel|grep hda

this will show you the kernel boot up information and tells you which
drive is found as drive 1 (hda)

be sure to get a disk which consumes low power. Maybe look for a 5400
UPM drive, look out the specs.
Someone in the list mentioned to use Seagate drives which seem to
consume less power than the
default one installed.

The Main Problem ist the temperature and the powerconsumption in fact of
the small power unit
and the very small air condition system build into the RaQ
example drives:
Maxtor 34098H4: seek=10,6W; idle=5,5W
Seagate ST340823A: seek=9,6W; idle=4,8W
IBM DTLA-305040: seek=8,6 W; idle=4,9W

regards

-- 

¸,ø¤°`°¤ø,¸_¸,ø¤°`°¤ø,¸_¸,ø¤°°¤ø,¸_¸,ø¤°`°¤ø,¸_¸,ø¤°°¤ø,¸

Götz Lohmann  |  D-Mannheim  |  Web-Developer & Sys-Admin
---------------------------------------------------------
He's the fellow that people wonder what he does and why
the company needs him, until he goes on vacation.